Everything that happens at the bottom corner of a tote.
The discharge assembly is where leaks, incompatibility and most late-afternoon phone calls originate. This page exists so you can identify what you have, decide what you need and order it without a conversation.
Order valves & adapters
Quantity, size and seat material is enough. Photos of an unknown thread are welcome.
Identify the valve you already have.
Butterfly valve
A flat handle that swings 90 degrees, a disc inside the bore, usually molded polypropylene with an elastomer seat. The default on almost every caged IBC. Cheap, fast to operate, excellent flow, mediocre at sealing against fine particulate.
Ball valve
A lever that rotates a bored ball. Seals more positively, costs more, handles particulate better and is the right upgrade when a butterfly valve weeps.
Gate or slide valve
Rare on IBCs, common on some European cages. A sliding plate. Replace with a butterfly if you can - parts are scarce.
Step two: measure the outlet
Nearly all North American IBC outlets are S60x6 buttress: a coarse 60 mm buttress thread. The usual confusion is with S75x6 on some 330 gallon units and with NPT on stainless vessels. Measure the outside diameter of the male thread: about 60 mm (2.36 in) is S60x6, about 75 mm (2.95 in) is S75x6.
Valves and adapters we keep on the shelf.
| Item | Connection | Seat | Flow | Service |
|---|---|---|---|---|
| 2 in. butterfly valve | S60x6 buttress | EPDM | Standard | General aqueous |
| 2 in. butterfly valve | S60x6 buttress | Viton | Standard | Solvent, fuel, oil |
| 3 in. butterfly valve | S75x6 buttress | EPDM | High | Viscous product |
| 2 in. ball valve | S60x6 buttress | PTFE seat | Standard | Positive shutoff |
| Camlock adapter, male | S60x6 to 2 in. cam | n/a | Standard | Hose connection |
| Camlock dust cap | 2 in. cam | Buna | n/a | Transport closure |
| NPT adapter | S60x6 to 2 in. NPT | n/a | Standard | Rigid plumbing |
| Garden hose adapter | S60x6 to 3/4 in. GHT | n/a | Low | Rain kits, irrigation |
| Tri-clamp adapter | S60x6 to 2 in. TC | n/a | Standard | Sanitary transfer |
| Valve extension | S60x6 both ends | n/a | Standard | Clearance over a bund |
Leaks and how to stop them.
01The valve weeps around the handle shaft.
The stem seal has hardened, usually from a chemical the seat was never rated for. Replace the valve; shaft seals are not serviceable on molded butterfly bodies.
02It drips at the thread where the valve meets the bottle.
Nine times out of ten the buttress gasket is missing, doubled or pinched. Back it off, inspect the gasket seat, use one new gasket and hand tighten plus a quarter turn with a strap wrench.
03The lid collapsed the bottle during discharge.
You drew a vacuum. Use a vented lid or crack the fill cap while draining. A collapsed bottle is often still usable but should be inspected before refilling.
04My camlock will not seat on the adapter.
Mixing brands and materials of cam arms is a classic. Also check for a leftover dust cap gasket inside the coupler.
05Can I reuse a gasket?
No. They are a dollar. The safety page explains why a reused gasket is the most common cause of a yard spill.
Identifying a thread with a tape measure.
Five measurements and a look at the profile will identify any fitting you are likely to meet on an IBC in North America.
| Measure this | If it reads | It is | Mating part |
|---|---|---|---|
| Male thread OD | 60 mm / 2.36 in | S60x6 buttress | 2" camlock or NPT adapter |
| Male thread OD | 75 mm / 2.95 in | S75x6 buttress | 3" camlock adapter |
| Fill opening OD | 150 mm / 5.9 in | S150x8 buttress | 6 in. vented or solid lid |
| Thread profile | Sawtooth, coarse | Buttress | Seals on a face gasket, not the thread |
| Thread profile | Tapered, fine | NPT | Seals on the thread, use tape or dope |
| Thread profile | Parallel, fine | BSP | Needs a bonded seal or washer |
| Ferrule OD | 64 mm / 2.5 in | 2" tri-clamp | Sanitary clamp and gasket |
| Hose thread OD | 26.4 mm / 1.04 in | 3/4" GHT | Garden hose fittings |
What comes out, and how fast.
Approximate gravity discharge of water from a full 275-gallon container. Viscous product will be dramatically slower.
| Outlet | Approx. flow | 275 gal drains in | Notes |
|---|---|---|---|
| 2" butterfly, open | 45-60 gal/min | 5-7 minutes | Slows markedly as the head drops |
| 2" ball valve | 40-55 gal/min | 6-8 minutes | Slightly more restriction, better shutoff |
| 2" camlock + 2" hose | 30-45 gal/min | 7-10 minutes | Hose length and bends matter |
| 3" butterfly | 90-120 gal/min | 3-4 minutes | Needs S75x6 outlet |
| 3/4" garden hose | 5-9 gal/min | 40-60 minutes | Rain kits and irrigation only |
| Pumped transfer | Pump dependent | Pump dependent | Vent the lid or collapse the bottle |
Ball, butterfly or diaphragm.
Three mechanisms cover almost everything in this trade. Picking correctly is mostly about viscosity, particulate and how often the valve will be cycled.
| Type | How it seals | Best for | Weak at | Cycle life |
|---|---|---|---|---|
| Ball valve | Rotating bore against two seats | Clean liquids, frequent use | Particulate chews the seats | High |
| Butterfly valve | Disc against a liner | Viscous product, high flow | Fine sealing at low pressure | Medium |
| Diaphragm valve | Flexible membrane onto a weir | Slurries, hygiene duty | Membrane fatigue | Medium |
| Plug valve | Tapered plug in a seat | Legacy fittings | Sticking after long storage | Low |
| Gate valve | Rising wedge | Rare on IBCs | Clogging, slow to operate | Low |
Changing an IBC valve without making a mess.
Fifteen minutes with two tools. The order matters, particularly the first step, which people skip and then regret.
Confirm it is empty
Open the lid and look. Do not trust the sight stripe or the last person to use it. Crack the valve into a bucket before touching the collar.
Back off the collar
Most outlets unscrew by hand or with a strap wrench. Never use a pipe wrench on the plastic collar - it will crack and you will need a new one.
Clean the sealing face
Wipe the collar face and inspect it for scoring. A damaged face will leak with any gasket. Replace the whole collar if it is scored.
Fit gasket and hand tighten
New gasket, correct elastomer for your cargo, then hand tight plus a quarter turn. Fill with water and watch it for five minutes before trusting it.
Where the leak actually is.
A dripping outlet has four possible sources and only one of them means you need a new valve. Work down this list in order before ordering anything.
| Symptom | Likely source | Test | Fix |
|---|---|---|---|
| Drip with valve closed | Valve seat worn or fouled | Cycle the valve several times, retest | Clean, or replace the valve |
| Weep at the collar | Face gasket hardened or misaligned | Dry the area, watch where the wet starts | New gasket, hand tight plus quarter turn |
| Drip from the handle | Stem seal failed | Look for wetness at the stem boss | Replace the valve - stem seals are not serviceable |
| Wet under the bottle | Bottle crack at the sump | Dry, chalk the area, fill and watch | Rebottle or condemn |
| Leak only when full | Hydrostatic head opening a crack | Fill to 90 percent and inspect | Rebottle |
| Leak only in cold | Freeze split, often hairline | Warm and inspect at the lowest point | Rebottle - never patch |
| Weep at the adapter | Wrong thread or missing gasket | Check thread form against the chart | Correct adapter and gasket |
| Overflow at the lid | Blocked vent | Check the vent hole in the cap | Clear or replace the vented lid |
Unknown thread? Send a photo.
Straight-on shot of the outlet with a tape measure in frame. We will name it and ship the adapter.
The numbers people ask us for twice a week.
Specifications, capability and contact details in one block, so you never have to go hunting for them from wherever you happen to be on this site.
- Buy used IBC totes, drums, cages and pallets nationwide
- Sell reconditioned, rebottled and food grade containers
- Hot caustic wash with counter-current triple rinse
- Food grade protocol in an isolated circuit with swab verification
- UN 31HA1 leak and pressure testing with reconditioner marking
- Cage straightening, revalving and full hardware replacement
- Freight booking: partial, consolidated and full truckload
- Managed container fleet programmes from 150 units
- On-site granulation into clean HDPE regrind
- Custom fabrication, plumbing, branding and upcycled builds
Write to us
Every message is read by a person in Dallas and answered within one business day.
Container fast reference.
Nominal figures for the containers we stock. Gross weights assume water at 8.345 lb per gallon - multiply by your product specific gravity.
| Container | Capacity | Footprint | Height | Tare | Gross (water) | Outlet |
|---|---|---|---|---|---|---|
| Caged IBC, standard | 275 gal / 1,041 L | 48" x 40" | 46" | 125 lb | 2,419 lb | S60x6 |
| Caged IBC, tall | 330 gal / 1,249 L | 48" x 40" | 53" | 148 lb | 2,902 lb | S60x6 |
| Caged IBC, low profile | 180 gal / 681 L | 48" x 40" | 35" | 104 lb | 1,606 lb | S60x6 |
| Caged IBC, compact | 120 gal / 454 L | 40" x 32" | 34" | 78 lb | 1,079 lb | S60x6 |
| Stainless IBC | 350 gal / 1,325 L | 48" x 42" | 51" | 320 lb | 3,241 lb | NPT / TC |
| Poly drum, tight head | 55 gal / 208 L | 23" dia. | 35" | 22 lb | 481 lb | 2" NPS |
| Steel drum, tight head | 55 gal / 208 L | 23" dia. | 34" | 38 lb | 497 lb | 2" NPS |
Five answers that apply wherever you are.
01What does a used IBC tote actually cost?
It depends on grade, quantity and your distance from Dallas, and freight is often the biggest single variable. Grade C units are a fraction of Grade A, rebottled sits near the top, and food grade is priced by scarcity of documented stock. Send a quantity and a zip code and you get a landed number, not a range. The pricing guide shows the bands we work in on the buy-back side.
02How fast can I get containers?
Stock units leave the yard in two to three business days, rebottled in two to five, food grade in three to seven. Add transit: next day in the Texas triangle, two to three days through the Midwest and Southeast, three to five to the coasts. Full lane detail is on the locations page.
03Will you buy the empties I already have?
Yes, in all 48 contiguous states, including damaged units and mixed unsorted lots. Freight is netted into the price so you see one clear per-unit number, and within 150 miles of Dallas collection is free. Details on we buy your totes.
04How do I know what grade I need?
Tell us the cargo rather than the grade. We publish a written grading standard and we will usually recommend a cheaper grade than people ask for, because most jobs do not need appearance. The Tote Matchmaker encodes the same conversation in four questions.
05Why is there no phone number anywhere on this site?
Because we have never had one. Written answers give you a record, a quote you can forward and a grade you can hold us to, and they are a large part of why every request gets answered within one business day. The form on this page reaches the same people a phone line would have.
Everything, from here.
Containers
Services
Reference
Looking for something that is not listed? The full site index has every page, including the inner pages that are not in the main menu.