Skip to content
Totes Nation
Dallas, TX · Est. 2009Get a quote
The deadline nobody tracks

Your fleet quietly falls out of compliance every 30 months.

Composite IBCs in regulated service need a leak test every 2.5 years and a full inspection and pressure test every 5. Most fleets discover this during an audit. We do the testing, the repairs and the remarking, and we will track the clock for you.

Fast lane

Book a test lot

Unit count and the last test date, if you know it. If you do not, that is a common and fixable situation.

Yard & office9003 Governors Row, Dallas, TX 75247hello@totesnation.com

A working business mailbox - we reply here.

US or Canadian number, 10 digits including area code

Two-letter code or full name

US ZIP (75247) or Canadian (M5V 3L9)

Whole units, 1 to 100,000

Please describe it in words - links are not accepted.

No phone tag. A human replies from Dallas within one business day.
The requirement

What 49 CFR actually asks for.

Short version, not legal advice - but it is the version that keeps fleets out of trouble.

IntervalRequirementApplies toOur service
Every 2.5 yearsLeak test and external inspectionComposite IBCs in regulated serviceTest, repair, mark, document
Every 5 yearsFull internal and external inspection plus leak testComposite IBCs in regulated serviceFull cycle with report
Before reuseInspection for damage and compatibilityAll IBCsIncluded in reconditioning
After repairRetest to original design typeRepaired unitsHydrostatic where required
Drum reconditioningLeak test and reconditioner markingSteel and poly drumsPer unit
In the test cell

What a recertification run looks like.

Receive & read

UN plate decoded, original design type and date captured, serial logged.

Inspect

Bottle, cage, pallet, welds and fittings checked against the design type.

Test

Leak test at specified pressure; hydrostatic where the repair history demands it.

Repair or condemn

Hardware replaced, cage pressed, or the unit leaves regulated service permanently.

Mark & document

Reconditioner mark and test date applied, certificate issued against the serial.

Fleet tracking

We will keep the calendar so you do not have to.

For managed and toll-wash customers we track test dates at serial level and tell you 90 days before a lot comes due. It costs nothing extra and prevents the most common compliance failure in liquid packaging: a perfectly good fleet that cannot legally carry regulated goods because a date passed.

If you do not know when your containers were last tested, we can usually reconstruct it from the plate and the markings. Send photos of a few plates and we will tell you where you stand.

How to read your UN plate
Compliance questions

Asked by people who just failed an audit.

01Our containers are overdue. What now?

They cannot carry regulated goods until tested, but they are not scrap. Send a lot, we test and remark them, and you are back in service in under a week.

02Can you test containers you did not sell us?

Yes. A large share of our testing volume is other people’s fleets.

03What fails most often?

Valve seats and gaskets, by a wide margin, followed by cage damage at the bottom rail. Both are repairs, not condemnations.

04Do you issue a certificate?

Yes, per serial, with test type, date, pressure and technician. Auditors ask for exactly this and we have the format they want.

05Does non-regulated cargo need testing?

Not legally in most cases. We still recommend a leak test before refilling anything that has been stored outdoors, because a yard spill costs more than a test.

Test detail

What each test actually involves.

Useful when an auditor asks what was done, rather than whether something was done.

TestMethodAcceptanceRecord produced
Leak testInternal air pressure held, container submerged or soap testedNo detectable leakage at specified pressurePass/fail against serial, with pressure and duration
External inspectionVisual of bottle, cage, pallet, welds, fittings and markingsNo crazing, cracked welds, breach or illegible plateCondition report
Internal inspectionVisual through fill opening with lightNo crazing, delamination or structural defectCondition report
Hydrostatic testWater-filled pressure test where repair history requiresHolds specified pressure without deformationCertificate with pressure and hold time
Stacking verificationDesign-type reference check against markingsMarking consistent with design typeNoted on certificate
RemarkingReconditioner mark and test date applied adjacent to original plateLegible and permanentPhotographed on request
Fleet audit

Reconstructing a compliance calendar from nothing.

The most common testing engagement we take is a fleet whose test history nobody can find. It is a solvable problem.

Photograph plates

Send clear photos of twenty representative UN plates. We decode design type and dates from them.

We map the fleet

Units grouped by design type and date band, with overdue, due-soon and current clearly separated.

Test the overdue

Send them in batches. Leak test, repair, remark and certificate per serial, usually under a week per batch.

Keep the calendar

We track dates at serial level and warn you 90 days out. It costs nothing and prevents the whole problem recurring.

The calendar

Every clock that runs on an IBC.

There are three separate intervals and people routinely conflate them. Missing any one of them takes the container out of legal service for regulated cargo.

Non-regulated cargo does not legally require any of this, but your insurer and your own risk assessment may still ask for it.
RequirementIntervalWhat it involvesMarking appliedConsequence of missing it
Leakproofness testEvery 30 monthsInternal air pressure, held and monitoredDate and reconditioner codeNot legal for liquid hazmat transport
Periodic inspectionEvery 30 monthsVisual, internal and external, fittingsLogged, markedSame
Full requalificationEvery 60 monthsLeakproofness plus hydrostatic, plus inspectionDate and codeContainer out of service
Initial design typeOnce, by manufacturerDrop, stack, vibration, hydrostaticUN plateNot a UN package at all
Stack test, design typeOnce, by manufacturerStacked load held 24 hoursReflected in the plate-
Repair revalidationAfter any repairRetest of the repaired unitReconditioner markingRepair not recognised
Failure data

What actually fails a test, from our own cell.

Roughly one in nine units that come to us for recertification fails. This is the distribution, and most of it is preventable at the customer site.

Units that fail are quoted for repair and retest before anything happens to them. Nothing gets condemned without your sign-off.
Failure modeShare of failuresRepairable?Prevented by
Valve or gasket leak34%Yes - replace and retestAnnual gasket replacement
Lid or vent leak18%Yes - replace and retestDo not over-tighten the lid
Bottle crazing or hairline crack21%No - rebottleShaded or indoor storage
Cage weld failure11%Sometimes - re-weld and retestDo not stack damaged cages
Illegible or missing UN plate8%No - the unit loses its ratingDo not paint over the plate
Outlet collar damage5%Yes - replace collarStrap wrench, never a pipe wrench
Pallet failure3%Yes - pallet swapAvoid wooden pallets in wet service
Reading the record

What a test certificate should say.

If you are receiving certificates from anyone, including us, these are the fields that make the document worth having in an audit file.

Container serial numberMandatory - ties paper to steel
UN design type codeAs read from the plate
Test dateDay, month, year
Next due dateCalculated, both 30 and 60 month
Test type performedLeakproofness, hydrostatic, or both
Test pressure and durationActual values, not 'per regulation'
ResultPass, fail, or pass after repair
Repairs carried outItemised, with parts
Reconditioner marking appliedCode and date
Signature and nameA person, not a department

A certificate without a serial number is not a certificate, it is a letter. The whole point of the document is that an auditor can pick a container off your rack, read the number on the tag and find the matching record. If the paperwork you are being given cannot do that, it will not survive the first serious audit you face.

The second thing auditors look for is the actual test values rather than a statement that the test was carried out in accordance with the regulation. Anyone can write the second sentence. Only someone who ran the test can write the first.

Next move

When was your fleet last tested?

If the answer is a shrug, send us photos of three UN plates and we will reconstruct the clock.

Reference · on every page for a reason

The numbers people ask us for twice a week.

Specifications, capability and contact details in one block, so you never have to go hunting for them from wherever you happen to be on this site.

Totes Nation at a glance
Founded2009
Head office & yardDallas, TX
Street address9003 Governors Row
ZIP75247
People71
Yard size9 acres, 11 dock doors
Wash capacity1,200 units/day
States served48
Quote turnaround1 business day
PhoneNone - email only
Everything we do
  • Buy used IBC totes, drums, cages and pallets nationwide
  • Sell reconditioned, rebottled and food grade containers
  • Hot caustic wash with counter-current triple rinse
  • Food grade protocol in an isolated circuit with swab verification
  • UN 31HA1 leak and pressure testing with reconditioner marking
  • Cage straightening, revalving and full hardware replacement
  • Freight booking: partial, consolidated and full truckload
  • Managed container fleet programmes from 150 units
  • On-site granulation into clean HDPE regrind
  • Custom fabrication, plumbing, branding and upcycled builds
Office & dock hours
Monday - Thursday7:00 AM - 5:00 PM CT
Friday7:00 AM - 3:00 PM CT
Saturday8:00 AM - 12:00 PM CT (dock pickups only)
SundayClosed

Write to us

Every message is read by a person in Dallas and answered within one business day.

Quick specification

Container fast reference.

Nominal figures for the containers we stock. Gross weights assume water at 8.345 lb per gallon - multiply by your product specific gravity.

Full dimensions, clearances, thread data and UN codes are in Sizes & Specs.
ContainerCapacityFootprintHeightTareGross (water)Outlet
Caged IBC, standard275 gal / 1,041 L48" x 40"46"125 lb2,419 lbS60x6
Caged IBC, tall330 gal / 1,249 L48" x 40"53"148 lb2,902 lbS60x6
Caged IBC, low profile180 gal / 681 L48" x 40"35"104 lb1,606 lbS60x6
Caged IBC, compact120 gal / 454 L40" x 32"34"78 lb1,079 lbS60x6
Stainless IBC350 gal / 1,325 L48" x 42"51"320 lb3,241 lbNPT / TC
Poly drum, tight head55 gal / 208 L23" dia.35"22 lb481 lb2" NPS
Steel drum, tight head55 gal / 208 L23" dia.34"38 lb497 lb2" NPS
Asked from every page

Five answers that apply wherever you are.

01What does a used IBC tote actually cost?

It depends on grade, quantity and your distance from Dallas, and freight is often the biggest single variable. Grade C units are a fraction of Grade A, rebottled sits near the top, and food grade is priced by scarcity of documented stock. Send a quantity and a zip code and you get a landed number, not a range. The pricing guide shows the bands we work in on the buy-back side.

02How fast can I get containers?

Stock units leave the yard in two to three business days, rebottled in two to five, food grade in three to seven. Add transit: next day in the Texas triangle, two to three days through the Midwest and Southeast, three to five to the coasts. Full lane detail is on the locations page.

03Will you buy the empties I already have?

Yes, in all 48 contiguous states, including damaged units and mixed unsorted lots. Freight is netted into the price so you see one clear per-unit number, and within 150 miles of Dallas collection is free. Details on we buy your totes.

04How do I know what grade I need?

Tell us the cargo rather than the grade. We publish a written grading standard and we will usually recommend a cheaper grade than people ask for, because most jobs do not need appearance. The Tote Matchmaker encodes the same conversation in four questions.

05Why is there no phone number anywhere on this site?

Because we have never had one. Written answers give you a record, a quote you can forward and a grade you can hold us to, and they are a large part of why every request gets answered within one business day. The form on this page reaches the same people a phone line would have.

Get a quote